Actel

Designer v5.2 Service Pack 1 Release Notes

Thank you for your interest in Actel's Designer v5.2 design implementation software. These v5.2 SP1 release notes outline new features and benefits, new device support, known limitations, and other information about this release.

Included Software

Back to top

This Service Pack only includes a patch or patches supporting Designer v5.2. Designer v5.2 software in total can be obtained from the Release Notes.

New Features and Enhancements

Back to top

This Service Pack does not contain new features or enhancements. This service pack addresses important fixes in the software.

Resolved Issues

Back to top

Workarounds are no longer required for Resolved Issues.

Timer

35508/36336 – v5.2 puts arbitrary numbers into the SDF file for register recovery time. In older versions, this recovery time for AX devices was 0.0ns. This SP1 resolves the problem by having approximate delays in the SDF file.

MultiView Navigator

35953 – In AX and RTAX devices, the RCLK/HCLK will automatically snap when they are illegally assigned. RCLK/HCLK I/Os can only be assigned to the P side of a paired I/O, however, if the user assigns it to the N-side of the pair either using MVN or PDC, the software will let the user proceed without a warning.

Also, snapping could result in similar issues with the LVDS/LVPECL I/O assignments in the PDC if the user assigns (switches) the N and P sides incorrectly (for example, if the user assigns the N side macro to the P-side I/O, software will not generate a warning and will silently switch the 2 assignments internally). The software does not error out when this type of illegal I/O assignment is done in PDC. In the MVN, however, the paired I/Os can only be moved together, and so they are assigned to the correct locations. SP1 resolves the above issues.

Linux RH 7.1

35845 – Designer v5.2 does not contain Flexlm utilities. lmdiag, lmgrd, lmutil, etc are missing from the ./bin directory of the Linux build of Designer v5.2. Designer cannot be launched. This issue is resolved in v5.2 SP1.

Miscellaneous

35585 – In AX devices, the PLL does not work with external feedback. A PLL with external feedback does not provide the correct output frequency. SP1 resolves this issue.

36028 – In AX and SX-A devices, the DL2A macro does not behave as documented. Row two of the Antifuse Macro Library Guide for Software v5.2 DL2A table is not true in simulation.
IFF CLR=1, G=0, D=1, PRE=1, then Q=undefined. For all other combinations, the latch behaves as expected. The documentation claims q=1 for this condition. SP1 resolves this issue.

New Known Issues and Workarounds

Back to top

Previous Known Issues and Workarounds

Back to top

Download and Install Designer v5.2 Service Pack 1

Back to top

The version of software that you requested is no longer the most current version available. Please download the most recent software update.

If you need this specific version of software, please contact Actel Tech Support:
Email: tech@actel.com
Phone: 1.800.262.1060