Silicon Sculptor v4.60.2 Windows Release Notes

(Oct 25, 2006)

Silicon Sculptor Windows v4.60.2 is a service pack of the Silicon Sculptor software for providing an Enhanced Integrity Test (EIT) for both RT54SX72S and RTSX72SU devices as well as RT54SX32S and RTSX32SU devices. The previous service pack v4.60.1 only provided EIT for RT54SX72S and RTSX72SU. This service pack provides EIT for both die sizes. Additionally, a new post-programming test is provided for all A42MX devices.

This service pack is a new general release of the Silicon Sculptor software and all customers are encouraged to download it.

Note

RT54SX-S and RTSX-SU
Starting with the v4.50.0 release and including all subsequent releases, RT54SX-S and RTSX-SU products require a Silicon Sculptor II programmer to program. Programming RT54SX-S and RTSX-SU products with Silicon Sculptor I has been discontinued.

SX-A
Starting with the v4.53.0 release and all subsequent releases, the programming enhancement to SX-A devices is implemented with the enhancement previously included in RT54SX-S and RTSX-SU devices. For all SX-A devices, new AFMs are available with the Libero/Designer 6.2 SP1 release. The v4.53.0 release of the Silicon Sculptor software can take advantage of these AFMs by automatically using new programming conditions previously only available in the RadTolerant family of devices. You may continue to use older AFMs because the software will automatically use the older programming conditions in this case. Silicon Sculptor II must be used to program with these new enhancements. A reduced but enhanced set of programming conditions is used for programming all SX-A devices on Silicon Sculptor I programmers.

Supported Platforms

Back to top

v4.60.2 Windows

  • Windows XP with SP1 or SP2
  • Windows 2000 with SP1, SP2, SP3, or SP4

Minimum System Requirements

Back to top
  • Pentium 133 or higher (Pentium 200 or higher recommended) processor
  • 64 MB of available memory for use
  • 50 MB of available hard disk space
  • VGA or higher-resolution video adapter (SVGA 256-color and 800x600 or higher resolution recommended)
  • For Windows 2000 and Windows XP systems, you must have administration rights to the local workstation for installation purposes.

New Features and Enhancements

Back to top
  • SARno58434: Add Enhanced Integrity Test (EIT) for RT54SX-S and RTSX-SU devices. This provides a standalone EIT for RT54SX-S and RTSX-SU devices as well as adds the EIT to the device programming flow for RT54SX-S and RTSX-SU devices.
  • SARno58860: Add charge pump active post programming check for A42MX products

SculptW GUI Update for Standalone Test

Program Tab

The Program tab now includes the Act_Verify1 command. See Figure 1. This will provide the user a standalone capability to run the EIT test.


Figure 1. Act_Verify

The Act_Verify command includes the Enhanced Integrity Test (EIT), so that it now provides Blank Check, EOP, .etc, and EIT.

1 To be consistent with SculptW, the Enhanced Integrity Test (EIT) may be added into the Act_Verify command. The Act_Verify command will then provide Blank Check, EOP, .etc, and EIT.

NOTE: RT54SX-S and RTSX-SU devices programmed with earlier versions of the Actel Silicon Sculptor software may be tested using this Service Pack and the included standalone Act_Verify command as illustrated above.