Silicon Sculptor v4.59.0 Windows Release Notes
(June 9, 2006)
Silicon Sculptor Windows v4.59.0 is a new general release of the Silicon
Sculptor software. This release features support for new devices in the
ProASIC3 and AX families as well as operational improvements.
Note:
RT54SX-S and RTSX-SU
Starting with the v4.50.0 release and including all subsequent releases,
RT54SX-S and RTSX-SU products require Silicon Sculptor II programmer
to program. Programming RT54SX-S and RTSX-SU products with Silicon
Sculptor I has been discontinued.
SX-A
Starting with the v4.53.0 release and all subsequent releases, programming
enhancement to SX-A devices is implemented with the enhancement previously
included in RT54SX-S and RTSX-SU devices. For all SX-A devices, new
AFMs are available with the Libero/Designer 6.2 SP1 release. The v4.53.0
release of Silicon Sculptor software can take advantage of these AFMs
by automatically using new programming conditions previously only available
in the Rad Tolerant family of devices. Older AFMs may continue to be
used and the software will automatically use the older programming
conditions in this case. Silicon Sculptor II must be used to program
with these new enhancements. A reduced but enhanced set of programming
conditions is used for programming all SX-A devices on Silicon Sculptor
I programmers.
v4.59.0 Windows
- Windows 2000 with SP1, SP2, SP3, or SP4
- Windows XP with SP1 or SP2
- Pentium 133 or higher (Pentium 200 or higher recommended) processor
- 64 MB of available memory for use
- 50 MB of available hard disk space
- VGA or higher-resolution video adapter (SVGA 256-color and 800x600
or higher resolution recommended)
- For Windows 2000 and Windows XP systems, you must have administration
rights to the local workstation for installation purposes.
- SARno53721: Sculpt shows the message (not qualified)
when using certain BP modules
- SARno53529: Error message should say "Antifuse" instead
of "fuse" (AX/S)
- SARno53453: Add Act Verify command for AXS
- SARno53420: Warn the user that AX2000 does not support
concurrent mode
- SARno53120: serialization message appears requesting
upgrade
- SARno52145: Add read device idcode in the sculptor
software for AX/AXS/SXS
- SARno49274: Need pop up during device selection
for SX-A/RTSX-S
- SARno47049: STP Player print statement processing
needs cleaned up
- SARno47047: STAPL player's Export Boolean array
limited to 32 bit
- SARno43387: SculptW returns AFM error when AFM loaded
via Jobmaster
- SARno41324: Fails to run concurrent session with
AX2000-FG1152.
- SARno53175: When loading A3P/E STAPL files, device
selector sees M7 devices.
- SARno53176: STAPL Device Entry dialog says STAPL/Jam
- SARno53315: Act Verify needs progress bar or update.
Without the progress bar, the software appears hanged.