Actel

Silicon Sculptor Software v3.79 DOS and v4.42.0 Windows Release Notes

(Mar 8, 2004)

Silicon Sculptor DOS v3.79 and Windows v4.42.0 combine all the features and support of previous releases of the software with support for new packages in the APA1000 and APA300 series.

Supported Platforms

Back to top

v3.79 DOS

  • Windows 98, Second Edition

v4.42.0

  • Windows NT 4.0 with SP5 or SP6
  • Windows 2000 with SP1 or SP2 or SP3 or SP4
  • Windows XP with SP1

Minimum System Requirements

Back to top
  • Pentium 133 or higher (Pentium 200 or higher recommended) processor
  • 64 MB of available memory for use
  • 50 MB of available hard disk space
  • VGA or higher-resolution video adapter (SVGA 256-color and 800x600 or higher resolution recommended)
  • For NT 4.0, Windows 2000 and Windows XP systems, you must have administration rights to the local workstation for installation purposes.

Device Support

Back to top

New Features and Enhancements

Back to top

Silicon Sculptor software now has support for the following devices:

  • APA1000-CQ352
  • APA1000-CQ208
  • APA300-CQ352
  • APA300-CQ208

Silicon Sculptor software now:

  • Automatically selects the correct package when given a STAPL file
  • Supports SMPA-352CQ-ACTEL and SMPA-208CQ-ACTEL adapter modules
  • Prevents securing blank devices (SX/SXA/EX)
  • Provides partial ChainBuilder support

Resolved Issues

Back to top
  • SARno33595: Adapter module dimensions for FG484 incorrect
  • SARno33539: AX Blankcheck should be at VPP=1.5V
  • SARno32123: Exit on the correct fuse failure

Known Issues and Workarounds

Back to top
  • SAR 29998: The stand-alone secure command does not function. When you secure the device (lock or permanent lock), the error message, "Action Name Invalid" appears. This is intended behavior.
  • SAR 30695: In Silicon Sculptor software 3.75 DOS (16 bit), the self-test is failing for all SMPA modules.
    Workaround: The self-test does not fail on any modules. The ISP module self-test gives the following message, "Testing Current regulators: You must install SM48D or SM48DB before continuing." After you install the SM48D or SM48DB module, the self-test continues.
  • SAR 30558: In Windows, the Path + Filename doesn't always fit into the text field.
  • Design Name Readback for Flash devices - support for this feature through STAPL programming will be available in a future version of the software.
  • ChainBuilder "CheckChain" action does not work: overshifting error, and lack of POWER_DOWN function.

Installation Instructions

Back to top

The version of software that you requested is no longer the most current version available. Please download the most recent software update.

If you need this specific version of software, please contact Actel Tech Support:
Email: tech@actel.com
Phone: 1.800.262.1060