Actel

Supported Platforms

Back to top

v3.69

  • Windows 98, Second Edition
v4.32
  • Windows NT 4.0 with SP5 or SP6
  • Windows 2000 with SP1 or SP2
  • Windows XP

Minimum System Requirements

Back to top
  • Pentium 133 or higher (Pentium 200 or higher recommended) processor with Microsoft Windows 95
  • 64 MB of available memory for use
  • 50 MB of available hard disk space
  • VGA or higher-resolution video adapter (SVGA 256-color and 800x600 or higher resolution recommended)
  • Microsoft IntelliMouse or compatible device
  • For NT 4.0 and Windows 2000 systems, you must have administration rights to the local workstation

Device Support

Back to top

New device support for the following device-package combinations:

  • AX1000 - FG676
  • AX1000 - FG484
  • AX500 - FG484
  • AX500 - FG484

Note: This release also provides support for ProASICPLUS devices with the -F speed grade.

New Features and Enhancements

Back to top

Flash Design Name Readback

The Silicon Sculptor software now supports the Design Name Readback for Flash devices. The Design Name Readback feature supports bitstream programming.

FineICC Self Test

The FineICC self test has been upgraded to test the FineICC circuit. This test determines if the FineICC circuit is functional. You can use the new self-test with any Antifuse programming module or the SM48D (or SM48DB) module. See Figure 1.
Install SM48D or SM48DB Requirements
Figure 1. Install SM48D or SM48DB Requirements

If you run the self test with the SM48D (or SM48DB) module and the error message "Error: ICC Regulator Failed" appears, the programmer failed the FineICC test as shown in Figure 2.
ICC Regulator Error Message
Figure 2. ICC Regulator Error Message

If you run the self test with any other Antifuse programming module and the error message "Testing current regulators: you must install SM48D or SM48DB before continuing" appears, the self test discovered a problem with the FineICC circuit. It is attempting to recalibrate the circuit with a SM48D (or SM48DB) module. Since the FINEICC circuit issue cannot be fixed by recalibration, installing a SM48D (or SM48DB) module and continuing the self test results in the error message: "Error 47: Self Test Failed. This unit may need service. Please call technical support" as shown in Figure 3.

Figure 3. Error 47 Message

Note: Figures 1-3 are in DOS mode. If you receive any of the above error messages, contact Actel technical support.

Resolved Issues

Back to top

None.

Known Issues and Workarounds

Back to top
  • A500K180 ISP broadcast programming with STAPL file generated from Designer R1-2003 SP1 or later - Silicon Sculptor v4.31 software returns an error message when you program an A500K180-ISP in broadcast mode. Single mode programming is not affected.
  • Design Name Readback for Flash devices - support for this feature through STAPL programming is not available until a future version of the software is released.

Installation and Licensing Instructions

Back to top

The version of software that you requested is no longer the most current version available. Please download the most recent software update.

If you need this specific version of software, please contact Actel Tech Support:
Email: tech@actel.com
Phone: 1.800.262.1060