FlashPro v3.1 Release Notes
FlashPro v3.1 combines all the features and support
of FlashPro v3.0
MicroSoft Windows - U.S. Version
- Windows 98, First or Second Edition
- Windows NT 4.0 with SP5 or later
- Windows 2000 with SP2 or later
- Windows XP
- FlashPro software requires JRE (Java Runtime Environment) v1.4 or
higher
- Pentium 133 or higher (Pentium 200 or higher recommended) processor
with Microsoft Windows 98 or higher
- 64 MB available memory
- 50 MB available hard disk space
- VGA or higher-resolution video adapter (SVGA 256-color and 800x600
or higher resolution recommended)
- Administration rights to your local workstation for Windows NT 4.0
and Windows 2000 systems
- Supports all Flash devices for FlashPro
- Supports ProASICPLUS in FlashPro Lite
The STAPL Player now supports PREIR, PREDR, POSTIR, and POSTDR commands
in the STAPL file for customers who manually edit their STAPL files.
For more information about these commands, see JEDEC STAPL standard,
JESD71, at www.jedec.org.
FlashPro Lite Support
- The FlashPro software v3.1 supports the new FlashPro Lite programmer.
- When processing the Connect command, the FlashPro software detects
if the hardware is FlashPro or FlashPro Lite, and responds accordingly.
File Open Filter
When using the File > Open command, the filter is set to .stp.
- 27073: If a board had more than three ProASICPLUS devices
connected to it and used an external power supply source for Vddp and
Vpp, previous versions of the FlashPro software detected the voltage
on Vpp and did not program the devices. The FlashPro software v3.1
resolves this issue and prevents the false detection of Vpp.
- 28330: The FlashPro Lite serial number does not display in the Log
window. It was displayed incorrectly in previous versions of the software.
- 28329: When connecting to FlashPro Lite, previous versions of the
FlashPro software displayed an incorrect message in the Log window.
FlashPro Lite does not supply power so the Log window in the FlashPro
v3.1 software displays the following message:
"FlashPro Lite does not support Vddp and Vdd power supply. User
needs to supply Vddp and Vdd from the target."